As the general office environment get computerized and systemized, there are not much various selections on suitable flooring materials. If Raised (Access) Floor is considered, suitable flooring cover, which must be antistatic, dust-free with efficient maintenance, easy installation and removal, is essential. ESD Control OA Tile is ideal for this application. ESD Control OA Tile is not only used as the

finishing cover of Raised (Access) Floor, but also installed directly on the cement floor.

Product Inquiry +

Reviews

There are no reviews yet.

Be the first to review “ESD Control OA Tile”

Need Help? Contact Us Leave Feedback

Category: .

Share

 

Marble OA tile

 

marble tile 설명 사진

 

Technical Specifications of ESD Control OA Tiles
Specification Test Standard ESD Control OA Tiles
Dissipative OA Tile Antistatic Marble OA Tile Antistatic Carpet OA Tile
FLOOR
CLASSIFICATION
Type of Floor covering EN649 Heterogeneous SD / Antistatic vinyl flooring
ASTM F 1700 Class Ⅲ – Type B, Heterogeneous Vinyl Tile with form backing
NFPA Life safety code 101 Class 1 – Interior Floor Finish
NFPA 99 Standard for health care facility Meets Standard
Floor Classification
(Wear rating/Static load resistance)
EN 685 Commercial : 34 / Industrial 43
Origin South Korea
No of Color 4 4 13
PHYSICAL
FEATURES
Tile Dimension Size Bevel cutting 500*500
ASTM F 536 : Size Tolerance
(<+/-0.4mm / 305 mm)
<+/-0.4mm / 305mm
Dimensional stability EN 434 / FED STD NO. 501a, M 6211 <0.25%
Squareness ASTM F 540 : Square tolerance
(<0.25 mm / 305 mm)
<0.51 mm / 305mm
0.30 mm
Wear Layer Thickness EN 429
Inter Layer 1.0 mm thickness chip inlaid Print film
Total thickness EN 428 5.0mm
ASTM F 386 :
Thickness Tolerance(+/-0.13mm)
Meets Standard
Weight / ㎡ EN 430 5.0 mm : 10+/-1kg/㎡
Wear Resistance
(Abrasion / Thickness loss)
EN 660 -1 <0.08
Abrasion Group EN 649 Group T
ASTM D 4060
(CS-17 Wheel, 1,000g, 1,000 cycles)
70 ㎎
Hardness ASTM D 2240 (Type D) 67
Residual indentation EN 433 / Din 51955 < 0.04 mm
ASTM F 1914(<8%) <8%
Static Load Limit ASTM F 970 3,000 pound / square inch ; Long term
Flexibility ASTM 137 No crack or breaking
Castors wheel test EN 425 No Damage
ELECTRICAL
FEATURE
Electrical resistance DIN 51953 / EN 1081 106 < R < 108 109 < R < 1012
ASTM F 150 / ESD F 7.1 / UL 779 1.0* 106 ~1.0*109 1.0*109 ~ 1.0*1012
FIRE
RESISTANCE
Critical Radiant Flux ASTN E 648 / NFPA 253 Class 1 ( 1.08 W / cm2)
Flame Spread ASTM E 162 / ASTM E 84 / NFPA 225 NFPA Class B / UBC Class Ⅱ(<75)
Smoke Density ASTM E 662 / NFPA 258 Passed (<450 Dmc)
Thermal conductivity DIN 52612 / NFX 10021 0.309 w/m-k
Underfloor heating DIN 52612 Suitable – Max 30℃
ASTM F 1514 (△E<8ave,max) <△E=8.0
CHEMICAL
RESISTANCE
Chemical Resistance EN 423 / DIN 51958 Excellent
ASTM D 543 / ASTN F 925 Excellent
SLIP
RESISTANCE
Slip Resistance (Wet) DIN 51130 / BGR181 (ZH1 / 571) R9
ADA Requirements >0.6
prEN 13893 0.89u
Slip Resistance (Dry) EN 13893 >0.3
LIGHT
RESISTANCE
Color fastness EN 20105-B 02 >6
ISO 105 B 02, Met.3 – DIN53389 7
Resistance to light ASTM F 1515 (△E<8 ave, max) <△E = 8
OTHER
PROPERTIES
Impact sound reduction ISO 717 /2 4 dB
Sound absorption ISO 140-8 / ISO 717 3 dB
Water absorption ASTN D 570 0.03 % water weight gain
Ease of Decontamination DIN 25415-1 / ISO 8690 Excellent
Recyclable Yes